Introduction
Assorted topics relevant to programming particle-based simulation codes and to using these codes for the modeling of a wide range of systems, notably complex fluids.
Molecular dynamics simulations
Special Usage Notes
By default LAMMPS normalizes the temperature by an amount , where is the system's total number of degrees of freedom and is the system's dimensionality. Subtracting accounts for the center-of-mass motion of the system. This is incorrect if the system has a proper frame of reference, e.g., when using a Langevin thermostat in which all particles interact with a stationary background solvent. In this case it is necessary to ensure is used instead of . To do this, use the command compute_modify as follows
compute myTemp all temp compute_modify myTemp extra 0 thermo_modify temp myTemp